AC CURRENT / VOLTAGE TRANSDUCERS  CA/CV

 
    FEATURE
 
  • For AC CURRENT, VOLTS / 1P2W, 3P3W
  • Accuracy: +/- 0.2% RO
  • Input Max. 10A, 500V, 50/60/400Hz
  • TRMS measuring is available in option
  • Aux. Power AC 115 / 230V +/- 15%, 50/60Hz;
  • Isolation Aux. Power 12Vdc, 24Vdc, 48Vdc, 110Vdc available in option
  • Self powered or Loop powered models available
  • Low output ripple
  • Dielectric strength 4000 Vac for 1 min. between input / Output / Power / Case
  • IEC 1010, IEC 414, IEC 688, ANSI C37.90a
  • Safety ; IEC1010, IEC 414, BS5458
  • High stability & low cost
  • Outside dimensions 1P: 55(W) x 75(H) X 118(D) mm; 3P: 100(W) x 75(H) X 118(D) mm
  • Wall or DIN rail mounting ( EN 50022 )
 
                                                    

 Search / Order /   Quotation / Data Sheet  / More Products

                                   

 

 

 

 

       ORDER INFORMATION :

Eg.    C V - 33 - A5 6 - V2 - A1


               ( Means: Voltage Avg. Transducer,  3Phase 3Wires,  Input: 0~5A, 60Hz, Output  0~5V,  Aux.Supply: AC115/220V )

Eg.    C A - 33 - A5 6 - V2 - A1
         ( Means: Current Avg. Transducer,  3Phase 3Wires,  Input: 0~5A, 60Hz, Output  0~5V,  Aux.Supply: AC115/220V )

 

 

C

Input Type
( CODE )

-

Connection
( CODE )

-

Input
( CODE )

 

Input Frequency
( CODE )

-

Output
(CODE )

-

Aux. Power
(CODE)

 

 

 

 

 

 

 

 

 

 

CODE INPUT TYPE
 

CODE

INPUT RANGE

 

CODE

INPUT FREQ.

 

CODE

OUTPUT RANGE

CODE

OUTPUT RANGE

 

CODE

AUX. POWER

 

 

 

 

 

 

A Current (Avg.)

 

  A1

0 ~ 1 A

 

5

50Hz±3Hz

 

A1

0 ~ 1 mA

V1

0 ~ 1 V

 

A1

AC 115/230

 

 

 

AT Current (Trms.)

 

 

 

V Voltage (Avg.)

 

  A5

0 ~ 5 A

 

6

60Hz±3Hz

 

A2

0 ~ 5 mA

V2

0 ~ 5 V

 

A2

AC380 V

 

 

 

 

 

 

VT Voltage (Trms.)

 

V1

0 ~ 150V

 

O

Specify

 

A3

0 ~ 10 mA

V3

0 ~ 10 V

 

A3

AC416 V

 

 

 

 

 

 

 

 

 

V3

0 ~ 300V

 

 

A4

0 ~ 20 mA

V4

1 ~ 5 V

 

D2

DC 24 V

 

 

 

 

 

 

 

 

 

V5

0 ~ 500V

 

 

 

 

A5

4 ~ 20 mA

VO

Specify

 

D4

DC 48 V

 

 

 

 

 

 

 

 

 

A0

 Specify (A I/P)

 

 

 

 

AO

 Specify

 

D1

DC110 V

 

 

 

 

 

 

CODE CONNECTION

 

 

 

 

 

 

D3

DC220 V

 

 

 

 

 

 

12

1Phase 2Wires

 

V0

Specify (V I/P)

 

 

LP Loop Powered

 

 

 

AS Self Powered

 

 

 

33

3Phase 3Wires

 

 

 

 

 

 

O

Specify

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  * Self Powered units cannot be used for the following Outputs: 4~20mA,1~5V and 2~10V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                           

   TERMS OF USE :  Copyright © 2000-2005  Peruvian Trust Systems Inc .  ALL RIGHTS RESERVED. 
                                 Use for any other purpose is expressly prohibited by law, and may result in severe civil and criminal
                                 penalties. Violators will be prosecuted to the maximum extent possible.

    Last modified: June 04, 2008