General Specifications

Size LS110 - 4.5" Square (Industry Market)
LS80 - 3.25" Square (Industry Market)
Accuracy
  • Accuracy: ±1.0% of full scale basic accuracy class.
    Specific accuracies:
    Rectifier type: ±1.5% @ 25°C calibrated to sine wave.
    Expanded scale Voltmeter: 0.3% of mid-scale.
    Power factor meter: ±1% of scale length from 20-100% of rated current on balanced system models; ±3% of scale length on unbalanced systems model types.
    Frequency meters: ±0.15Hz and 45-55Hz and 55-65Hz, ±0.093Hz @ 58-62Hz, ±1.5Hz @ 350-450Hz.
  • Position of use: Vertical (Scale).
  • Full scale deflection: 250°
  • Operating temperature: 0 to 40°C (32 to 104°F).
  • Storage Temperature: -10 to 50°C (-4 to 123°F).
Enclosure
  • Glass window, ABS Resin Frame and case, PC Glass fiber base Mounting fittings included.
  • Terminal plate: Phenol resin material
Overload
  • Dielectric level: 2300 VAC for 1 minute between the electrical circuit and mounting studs.
  • Overload rating: Voltmeter and potential coils - 1.2X rating (continuous). AC Ammeters - 2X rating (continuous), and 10X rating for one second. Current coils (other than ammeters) 1.5X rating (continuous), and 10X rating for one minute.
  • Response time: Approximately 2.5 seconds
CT Burden All Ammeters & Power Meters - 0.5VA Maximum
Standards CEI 85, EN 60051, IEC414, VDE 0410, UNE 31318
DIN 43780, IEC51,  ANSI C39.1
Protection Degree:(CEI 70-1, IEC 529) IP52 for the case.
Protection Degree:(CEI 70-1, IEC 529) IP 00 for terminals.
Approvals CE, UL
Available Options
Custom Calibration
Order or RFQ Form

         PRICES

AC Voltmeter 

AC Ammeter 

Frequency Meters

Kilowatts Meter

Power Factor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Part Numbers - LS110                 LS110 Mechanical Drawing
4.5" AC Voltmeters  ( Rectifier Type )
Model Input Scale  
LS110150V150V 0-150VAC 0-150VAC  
LS110300V300V 0-300VAC 0-300VAC  
LS110500V500V 0-500VAC 0-500VAC  
LS110600V600V 0-600VAC 0-600VAC  
       
For Ranges higher than 600VAC, use external Potential Transformer with a 150 VAC Voltmeter.

Note: * = advise desired PT ratio / end scale value.

 

 

 

 

 

 

 

 

4.5" Frequency Meters
Model Input Scale
LS110HZ5565-A 120V, AC 55-65HZ
LS110HZ4565-A 120V, AC 45-65HZ
LS110HZ4555-A 120V, AC 45-55HZ
LS110HZ5565-B 240V, AC 55-65HZ
LS110HZ4565-B 240V, AC 45-65HZ
LS110HZ4555-B 240V, AC 45-55HZ
4.5" DC Voltmeters ( Moving Coil Type )
Model Input Scale
LS110DC30V30V 0-30V, DC 0-30V, DC
LS110DC50V50V 0-50V, DC 0-50V, DC
LS110DC100V100V 0-100V, DC 0-100V, DC
LS110DC150V150V 0-150V, DC 0-150V, DC
LS110DC300V300V 0-300V, DC 0-300V, DC
LS110DC500V500V 0-500V, DC 0-500V, DC
LS110DC600V600V 0-600V, DC 0-600V, DC
For Ranges higher than 600VDC, use external multiplier with 1mA Voltmeter

Note: * = advise desired PT ratio / end scale value.

4.5" AC Ammeters ( Rectifier Type )
Model Input Scale
LS1101A20A 0-1A, AC 0-20A, AC
LS1105A50A 0-5A, AC 0-50A, AC
LS1105A100A 0-5A, AC 0-100A, AC
LS1105A150A 0-5A, AC 0-150A, AC
LS1105A200A 0-5A, AC 0-200A, AC
LS1105A**A 0-5A, AC 0-**A, AC
For Ranges higher than 5AAC, use external Current Transformer CT with a 5AAC Ammeter.

Note: ** = advise desired CT ratio / end scale value.

4.5" DC Ammeters ( Moving Coil Type )
Model Input Scale
LS110DC1A1A 1ADC 0-1A, DC
LS110DC1.5A1.5A 1.5ADC 0-1.5A, DC
LS110DC2A2A 2ADC 0-2A, DC
LS110DC3A3A 3ADC 0-3A, DC
LS110DC5A5A 5ADC 0-5A, DC
LS110DC10A10A 10ADC 0-10A, DC
LS110DC15A15A 15ADC 0-15A, DC
LS110DC20A20A 20ADC 0-20A, DC
LS110DC30A30A 30ADC 0-30A, DC
LS110DC50MV50A 0-50mV, DC 0-50A, DC
LS110DC50MV100A 0-50mV, DCDC 0-100A, DC
LS110DC50MV***A 0-50mV, DC 0-***A, DC
Note: * = advise desired Shunt ratio / end scale value.

For Ranges higher than 30ADC, use external shunt with 50mVDC ammeter.

4.5" Kilowatt Meters
Model System Input Scale CT Ratio PT Ratio
LS110KW12A 1 Phase-2Wire (1EL) 120V - 5AAC Advise Advise Advise
LS110KW12B 1 Phase-2Wire (1EL) 120V - 1AAC Advise Advise Advise
LS110KW12C 1 Phase-2Wire (1EL) 240V - 5AAC Advise Advise Advise
LS110KW33A 3 Phase-3Wire (2EL) 120V (L-L) - 5AAC Advise Advise Advise
LS110KW33B 3 Phase-3Wire (2EL) 240V (L-L) - 5A AC Advise Advise Advise
LS110KW34 3Ph-4Wire (2.5EL) 120V (L-N) - 5AAC Advise Advise Advise
4.5" Power Factor Meters
Model System Input Scale
LS110PF12A 1 Phase - 2 Wire 120V - 5A, AC (0.5) lead-1-(0.5) lag
LS110PF12B 1 Phase - 2 Wire 240V - 5A, AC (0.5) lead-1-(0.5) lag
LS110PF33A
(Bal. Load)
3 Phase - 3 Wire 120V - 5A, AC (0.5) lead-1-(0.5) lag
LS110PF33B
(Bal. Load)
3 Phase - 3 Wire 240V - 5A, AC (0.5) lead-1-(0.5) lag
LS110PF34A
(Bal. Load)
3 Phase - 4 Wire 120V - 5A, AC (0.5) lead-1-(0.5) lag
LS110PF34B
(Bal. Load)
3 Phase - 3/4 Wire 240V - 5A, AC (0.5) lead-1-(0.5) lag


Standard Part Numbers - LS80                 LS80 Mechanical Drawing
3.25"  AC Voltmeters ( Rectifier Type )
Model Input Scale
LS80150V150V 0-150V, AC 0-150V, AC
LS80300V300V 0-300V, AC 0-300V, AC
LS80300V500V 0-500V, AC 0-500V, AC
LS80600V600V 0-600V, AC 0-600V, AC
LS80150V600V 0-150V, AC 0-600V, AC
LS80150V*V 0-300V, AC 0-*V, AC
For Ranges higher than 600VAC, use external Potential Transformer with a 150 VAC Voltmeter.

Note: * = advise desired PT ratio / end scale value.

 

 

 

 

 

 

 

3.25" DC Voltmeters( Moving Coil Type )
Model Input Scale
LS80DC30V30V 0-30V, DC 0-30V, DC
LS80DC50V50V 0-50V, DC 0-50V, DC
LS80DC100V100V 0-100V, DC 0-100V, DC
LS80DC150V150V 0-150V, DC 0-150V, DC
LS80DC300V300V 0-300V, DC 0-300V, DC
LS80DC300V500V 0-500V, DC 0-500V, DC
LS80DC300V600V 0-600V, DC 0-600V, DC
3.25"  AC Ammeters  ( Rectifier Type )
Model Input Scale
LS801A20A 0-1A, AC 0-20A, AC
LS805A50A 0-5A, AC 0-50A, AC
LS805A100A 0-5A, AC 0-100A, AC
LS805A150A 0-5A, AC 0-150A, AC
LS805A200A 0-5A, AC 0-200A, AC
LS805A**A 0-5A, AC 0-**A, AC
Note: ** = advise desired CT ratio / end scale value.
3.25" DC Ammeters ( Moving Coil Type )
Model Input Scale
LS80DC1A1A 1ADC 0-1A, DC
LS80DC1.5A1.5A 1.5ADC 0-1.5A, DC
LS80DC2A2A 2ADC 0-2A, DC
LS80DC3A3A 3ADC 0-3A, DC
LS80DC5A5A 5ADC 0-5A, DC
LS80DC10A10A 10ADC 0-10A, DC
LS80DC15A15A 15ADC 0-15A, DC
LS80DC20A20A 20ADC 0-20A, DC
LS80DC30A30A 30ADC 0-30A, DC
LS80DC50MV50A 0-50mV, DC 0-50A, DC
LS80DC50MV100A 0-50mV, DCDC 0-100A, DC
LS80DC50MV***A 0-50mV, DC 0-***A, DC
Note: * = advise desired Shunt ratio / end scale value.
3.25" Frequency Meters
Model Input Scale
LS80HZ5565-A 120V, AC 55-65HZ
LS80HZ4565-A 120V, AC 45-65HZ
LS80HZ4555-A 120V, AC 45-55HZ
LS80HZ5565-B 240V, AC 55-65HZ
LS80HZ4565-B 240V, AC 45-65HZ
LS80HZ4555-B 240V, AC 45-55HZ
 

 



TERMS OF USE :  Copyright © 2007-2010.  ALL RIGHTS RESERVED.
Use for any other purpose is expressly prohibited by law, and may result in severe civil and criminal penalties. Violators will be prosecuted to the fullest extent of the Law.
Last modified: August 08, 2010
  Web Master: O.A.D. - PTS Staff