SF-48 / SF-72 / SF-96 Series
|
General
Specifications
|
| Size |
SF-48
: 48 X 48
mm
SF-72 : 72 X 72 mm
SF-96 : 96 X 96 mm |
| Accuracy |
- SF-48 Amp/Volts
Class 1.5
- SF-72,96 Amp/Volts Class 1.5
- SF-72,96 KW &
Var Class 1.5
- SF-72,96
Power Factor, COS Ø 4 Degrees in Phase
Angle
- SF-72,96 Hz Class
1.5
- Position of
use: Vertical (Scale).
- Full scale
deflection: 90° and 250°
- Working
temperature 20°C (+/-10°C), Working Range between -25°C
and +55°C
- Storage
Temperature: -10 to 50°C (-4 to 123°F).
|
| Humidity |
- Ambient
relative humidity 85% without condensing, with 35°C
temperature for max. 60 days per year. Yearly average
humidity must beenhigher than 65% (DIN 40040)
|
| Enclosure |
- ABS Resin
frame and case & PC Material.
- Protection
Degree ( CEI 70-1, IEC 529 ) IP 52 for the case.
- Protection
Degree ( CEI 70-1, IEC 529 ) IP 00 For Terminals.
|
| Overload |
- Dielectric
level: 2000 VAC for 1 minute between the electrical circuit
and mounting studs.
- Insulation
Reference Voltage : 0.6Kv
- All
amperometric circuits support an overload of 1.2X rating
(continuous) and 10X during 5 Sec.
All Voltmetric circuits support an overload of 1.2X rating(
Continuous ) and 2X rating during 5 Sec.
- Response
time: Approximately 2.5 seconds
|
| CT
Burden |
All
Ammeters & Power Meters - 0.5VA Maximum |
| Standards |
CEI
85, EN 60051, IEC414, VDE 0410, UNE 21318
DIN 43780, IEC51, ANSI
C39.1
|
| Approvals |
CE,
UL |
| Available
Options |
| Custom
Calibration |
|
Order
or RFQ Form
PRICES
AC
Voltmeters
AC Ammeters
Wattmeters
Varmeters
Power
Factor
|
|
AC
VOLTMETERS
|
48x48mm
90°AC Voltmeters
(Moving
Iron Type ) |
|
Model
|
Input
|
Scale
|
|
SF48-90-100V100V
|
0-100VAC
|
0-100VAC
|
|
SF48-90-300V300V
|
0-300VAC
|
0-300VAC
|
|
SF48-90-500V500V
|
0-500VAC
|
0-500VAC
|
|
SF48-90-600V600V
|
0-600VAC
|
0-600VAC
|
|
|
|
|
|
72x72mm
90°AC Voltmeters
(Moving
Iron Type ) |
|
Model
|
Input
|
Scale
|
|
SF72-90-100V100V
|
0-100VAC
|
0-100VAC
|
|
SF72-90-300V300V
|
0-300VAC
|
0-300VAC
|
|
SF72-90-500V500V
|
0-500VAC
|
0-500VAC
|
|
SF72-90-600V600V
|
0-600VAC
|
0-600VAC
|
|
|
|
|
72x72mm
250°AC Voltmeters
(250° please ask if available)
(Moving
Iron Type ) |
|
Model
|
Input
|
Scale
|
|
SF72-250-100V100V
|
0-100VAC
|
0-100VAC
|
|
SF72-250-300V300V
|
0-300VAC
|
0-300VAC
|
|
SF72-250-500V500V
|
0-500VAC
|
0-500VAC
|
|
SF72-250-600V600V
|
0-600VAC
|
0-600VAC
|
|
|
|
|
96x96mm
90°AC Voltmeters
(Moving
Iron Type ) |
|
Model
|
Input
|
Scale
|
|
SF96-90-100V100V
|
0-100VAC
|
0-100VAC
|
|
SF96-90-300V300V
|
0-300VAC
|
0-300VAC
|
|
SF96-90-500V500V
|
0-500VAC
|
0-500VAC
|
|
SF96-90-600V600V
|
0-600VAC
|
0-600VAC
|
|
|
|
|
96x96mm
250°AC Voltmeters
(250° please ask if available)
(Moving
Iron Type ) |
|
Model
|
Input
|
Scale
|
|
SF96-250-100V100V
|
0-100VAC
|
0-100VAC
|
|
SF96-250-300V300V
|
0-300VAC
|
0-300VAC
|
|
SF96-250-500V500V
|
0-500VAC
|
0-500VAC
|
|
SF96-250-600V600V
|
0-600VAC
|
0-600VAC
|
|
|
|
AC
AMMETERS
|
48x48mm
90°AC Ammeters
(Rectifier
Type ) |
|
Model
|
Input
|
Scale
|
|
SF48-90-5A5A-DF1
|
0-5AAC
|
0-5AAC
|
|
SF48-90-10A10A-DF1
|
0-10AAC
|
0-10AAC
|
|
SF48-90-15A15A-DF1
|
0-15AAC
|
0-15AAC
|
|
SF48-90-20A20A-DF1
|
0-20AC
|
0-20AAC
|
|
SF48-90-25A25A-DF1
|
0-25AAC
|
0-25AAC
|
|
SF48-90-30A30A-DF1
|
0-30AAC
|
0-30AAC
|
|
SF48-90-40A40A-DF1
|
0-40AAC
|
0-40AAC
|
|
|
|
|
48x48mm
90°AC Ammeters
(Rectifier
Type ) |
|
Model
|
Input
|
Scale
|
|
SF48-90-5A50A-CTF1-10
|
0-5AAC
|
0-50AAC
|
|
SF48-90-5A60A-CTF1-12
|
0-5AAC
|
0-60AAC
|
|
SF48-90-5A75A-CTF1-15
|
0-5AAC
|
0-75AAC
|
|
SF48-90-5A100A-CTF1-20
|
0-5AAC
|
0-100AAC
|
|
SF48-90-5A120A-CTF1-24
|
0-5AAC
|
0-120AAC
|
|
SF48-90-5A150A-CTF1-30
|
0-5AAC
|
0-150AAC
|
|
SF48-90-5A200A-CTF1-40
|
0-5AAC
|
0-200AAC
|
|
SF48-90-5A
**
A-CTF1-**/5
|
0-5AAC
|
0-
**
AAC
|
|
Note:
**
= Advise desires CT ratio/end Scale
|
|
|
72x72mm
90°AC Ammeters
(Rectifier
Type ) |
|
Model
|
Input
|
Scale
|
|
SF72-90-1A1A-DF1
|
0-1AAC
|
0-1AAC
|
|
SF72-90-5A5A-DF1
|
0-5AAC
|
0-5AAC
|
|
SF72-90-10A10A-DF1
|
0-10AAC
|
0-10AAC
|
|
SF72-90-15A15A-DF1
|
0-15AAC
|
0-15AAC
|
|
SF72-90-20A20A-DF1
|
0-20AC
|
0-20AAC
|
|
SF72-90-25A25A-DF1
|
0-25AAC
|
0-25AAC
|
|
SF72-90-30A30A-DF1
|
0-30AAC
|
0-30AAC
|
|
SF72-90-40A40A-DF1
|
0-40AAC
|
0-40AAC
|
|
SF72-90-50A50A-DF1
|
0-50AAC
|
0-50AAC
|
|
SF72-90-60A60A-DF1
|
0-60AAC
|
0-60AAC
|
|
|
|
|
72x72mm
90°AC Ammeters
(Rectifier
Type ) |
|
Model
|
Input
|
Scale
|
|
SF72-90-5A50A-CTF1-10
|
0-5AAC
|
0-50AAC
|
|
SF72-90-5A60A-CTF1-12
|
0-5AAC
|
0-60AAC
|
|
SF72-90-5A75A-CTF1-15
|
0-5AAC
|
0-75AAC
|
|
SF72-90-5A100A-CTF1-20
|
0-5AAC
|
0-100AAC
|
|
SF72-90-5A120A-CTF1-24
|
0-5AAC
|
0-120AAC
|
|
SF72-90-5A150A-CTF1-30
|
0-5AAC
|
0-150AAC
|
|
SF72-90-5A200A-CTF1-40
|
0-5AAC
|
0-200AAC
|
|
SF72-90-5A1KA-CTF1-200
|
0-5AAC
|
0-1KAAC
|
|
SF72-90-5A1.5KA-CTF1-300
|
0-5AAC
|
1.5KAAC
|
|
SF72-90-5A
**A-CTF1-**/5
|
0-5AAC
|
0-
**
AAC
|
|
Note:
**
= Advise desires CT ratio/end Scale
|
|
|
72x72mm
250°AC Ammeters
(250°
please ask if available)
(Rectifier
Type ) |
|
Model
|
Input
|
Scale
|
|
SF72-250-1A1A-DF1
|
0-1AAC
|
0-1AAC
|
|
SF72-250-5A5A-DF1
|
0-5AAC
|
0-5AAC
|
|
SF72-250-5A50A-CTF1-10
|
0-5AAC
|
0-50AAC
|
|
SF72-250-5A60A-CTF1-12
|
0-5AAC
|
0-60AAC
|
|
SF72-250-5A75A-CTF1-15
|
0-5AAC
|
0-75AAC
|
|
SF72-250-5A100A-CTF1-20
|
0-5AAC
|
0-100AAC
|
|
SF72-250-5A120A-CTF1-24
|
0-5AAC
|
0-120AAC
|
|
SF72-250-5A150A-CTF1-30
|
0-5AAC
|
0-150AAC
|
|
SF72-250-5A200A-CTF1-40
|
0-5AAC
|
0-200AAC
|
|
SF72-250-5A1KA-CTF1-200
|
0-5AAC
|
0-1KAAC
|
|
SF72-250-5A1.5KA-CTF1-300
|
0-5AAC
|
1.5KAAC
|
|
SF72-250-5A
**
A-CTF1-**/5
|
0-5AAC
|
0-
**
AAC
|
|
Note:
**
= Advise desires CT ratio/end Scale
|
|
|
WATTMETERS
|
72 x 72 mm BE-72
WATTMETERS 90°
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF72-90W12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90W12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90W12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90W33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90W33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF72-90W34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
72 x 72 mm
WATTMETERS 250°
(250°
please ask if available)
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF72-250W12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250W12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250W12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250W33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250W33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF72-250W34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
96 x 96 mm BE-96
WATTMETERS 90°
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF96-90W12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90W12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90W12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90W33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90W33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF96-90W34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
96 x 96 mm
WATTMETERS 250°
(250°
please ask if available)
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF96-250W12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250W12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250W12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250W33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250W33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF96-250W34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
VARMETERS
|
72 x 72 mm BE-72
VARMETERS 90°
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF72-90V12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90V12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90V12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90V33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-90V33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF72-90V34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
72 x 72 mm
VARMETERS 250°
(250°
please ask if available)
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF72-250V12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250V12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250V12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250V33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF72-250V33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF72-250V34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
96 x 96 mm BE-96
VARMETERS 90°
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF96-90V12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90V12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90V12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90V33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-90V33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF96-90V34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
96 x 96 mm
VARMETERS 250°
(250° please
ask if available)
|
|
Model
|
System
|
Input
|
Scale
|
CT Ratio
|
PT Ratio
|
|
SF96-250V12A
|
1
Phase - 2 Wire (1EL)
|
120V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250V12B
|
1
Phase - 2 Wire (1EL)
|
120V
- 1AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250V12C
|
1
Phase - 2 Wire (1EL)
|
240V
- 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250V33A
|
3
Phase - 3 Wire (2EL)
|
120V
(L-L) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
SF96-250V33B
|
3
Phase - 3 Wire (2EL)
|
240V
(L-L) - 5A AC
|
Advise
|
Advise
|
Advise
|
|
SF96-250V34
|
3
Phase - 4 Wire (2.5EL)
|
120V
(L-N) - 5AAC
|
Advise
|
Advise
|
Advise
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
POWER FACTOR METERS
|
72 x 72 mm BE-72 POWER FACTOR METERS 90°
|
|
Model
|
System
|
Input
|
Scale
|
CT
|
PT
|
|
SF72-90PF12A
|
1
Phase - 2 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-90PF12B
|
1
Phase - 2 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-90PF33A (Bal. Load)
|
3
Phase - 3 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-90PF33B (Bal. Load)
|
3
Phase - 3 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-90PF34A (Bal. Load)
|
3
Phase - 4 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-90PF34B (Bal. Load)
|
3
Phase - 3/4 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
72 x 72 mm BE-72
POWER FACTOR METERS 250°
(250°
please ask if available)
|
|
Model
|
System
|
Input
|
Scale
|
CT
|
PT
|
|
SF72-250PF12A
|
1
Phase - 2 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-250PF12B
|
1
Phase - 2 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-250PF33A (Bal. Load)
|
3
Phase - 3 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-250PF33B (Bal. Load)
|
3
Phase - 3 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-250PF34A (Bal. Load)
|
3
Phase - 4 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF72-250PF34B (Bal. Load)
|
3
Phase - 3/4 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
96 x 96 mm BE-96 POWER FACTOR METERS 90°
|
|
Model
|
System
|
Input
|
Scale
|
CT
|
PT
|
|
SF96-90PF12A
|
1
Phase - 2 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-90PF12B
|
1
Phase - 2 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-90PF33A (Bal. Load)
|
3
Phase - 3 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-90PF33B (Bal. Load)
|
3
Phase - 3 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-90PF34A (Bal. Load)
|
3
Phase - 4 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-90PF34B (Bal. Load)
|
3
Phase - 3/4 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
96 x 96 mm BE-96
POWER FACTOR METERS 250°
(250°
please ask if available)
|
|
Model
|
System
|
Input
|
Scale
|
CT
|
PT
|
|
SF96-250PF12A
|
1
Phase - 2 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-250PF12B
|
1
Phase - 2 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-250PF33A (Bal. Load)
|
3
Phase - 3 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-250PF33B (Bal. Load)
|
3
Phase - 3 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-250PF34A (Bal. Load)
|
3
Phase - 4 Wire
|
120V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
SF96-250PF34B (Bal. Load)
|
3
Phase - 3/4 Wire
|
240V
- 5A, AC
|
(0.5)
lead-1-(0.5) lag
|
N/A
|
N/A
|
|
Note: **
= Advise desires CT , PT
ratio and end Scale
|
|
|